Why is there no VDC sub view in OneClick for Nexus 7000?

Document ID : KB000117203
Last Modified Date : 09/10/2018
Show Technical Document Details
Question:
The Nexus 7000 uses Virtual Device Contexts but there is no VDC subview in OneClick for this device.
Why not?
Answer:
The required data to populate the VDC in the information tab is missing from the mib.
This can be verified by an SNMP dump where we have no entry for 
1.3.6.1.4.1.9.9.774.1.3.1.1    ciscoVdcExtEntry  

http://oidref.com/1.3.6.1.4.1.9.9.774.1.3.1 

OID    Name    Sub children    Sub Nodes Total    Description 
1.3.6.1.4.1.9.9.774.1.3.1.1    ciscoVdcExtEntry    16    16    Each row contains additional information of a VDC instance. 

Information by cisco 
ciscoVdcExtTable OBJECT-TYPE 
SYNTAX SEQUENCE OF CiscoVdcExtEntry 
MAX-ACCESS not-accessible 
STATUS current 
DESCRIPTION 
"This table contains additional information of a VDC instance. There will be an entry for each VDC instance created in the system." 
::= { ciscoVdcExt 1 } 

If the vendor does not populate it in the mib, we cannot populate it in OneClick.  After discussing this with the Vendor, he confirmed that it is not available.