Why does WA_Links show correctly under Universe Topology, but when I check the topology through a Global Collection the WA_Links are missing and it shows the devices directly connected

Document ID : KB000100300
Last Modified Date : 06/06/2018
Show Technical Document Details
Question:
In OneClick, when I see the devices from the Universe topology, the WA_Links are being shown in between devices, but when I check the Global Collection Topology for the same devices the WA_Links are missing, how can I get the Global Collection Topology to correctly show the WA_Links?
Environment:
Spectrum 10.0
Spectrum 10.1
Spectrum 10.2
Answer:
There is an option to not show the WA_Links in OneClick as it may cause performance issues for the OneClick server.  If you want to see the WA_Links then please check the following options

OneClick Administration page - Adminstration tab, Web Server Performance - Infer Pipes in Global Collections

This option needs to be set to yes to show the WA_Links from the Global Collection topology.