Why do I have a RC=12 when applying CAS9E10 and CBUJE00 fmids?

Document ID : KB000012385
Last Modified Date : 14/02/2018
Show Technical Document Details
Introduction:

You are installing CA Common Services R14.1

Your job ended with a RC=12 when you applied CAS9E10 and CBUJE00 fmids.

The following errors are found in your apply joblog:

IEW2470E 9511 ORDERED SECTION CALLSXDC NOT FOUND IN MODULE.
IEW2470E 9511 ORDERED SECTION CAS9STAE NOT FOUND IN MODULE.
IEW2648E 5111 ENTRY CAS9STAE IS NOT A CSECT OR AN EXTERNAL NAME IN THE MODULE.
IEW2648E 5111 ENTRY CAS9SYMD IS NOT A CSECT OR AN EXTERNAL NAME IN THE MODULE.
IEW2648E 5111 ENTRY CAS9USRI IS NOT A CSECT OR AN EXTERNAL NAME IN THE MODULE.
IEW2648E 5111 ENTRY CAS9DBES IS NOT A CSECT OR AN EXTERNAL NAME IN THE MODULE.

 

Question:

Why do I have a RC=12 when I apply CAS9E10 and CBUJE00 fmids?

Environment:
CA COMMON SERVICES R14.1 -
Answer:

If you want to use only CAIRIM, then you have to install CAS9E10, also CAW1E10 (CAIRIM) and CEI0E10(CAMASTER).

If it is NOT the case, all components found in the BASE pax file must be installed.

 