Issue:

In the Sysview -MVS monitor option 6 (DB2 option) any selection to view a specific DB2 substem's metrics always reverts back to the first subsystem

defined.  After selecting a subsequent DB2 ssid from the DB2 list,  the information provided always reverts back to the first DB2 subsystem that was

selected.  The IDB2 DC job shows: (rc 204) Xnet request failed (rs 273) Xnet Duplicate Agent.  

Environment:
Sysview -MVS monitor DB2 Option (6), Sysview Performance Management Option for DB2 for z/OS (IDB2).
Cause:

The  (rc 204) Xnet request failed (rs 273) Xnet Duplicate Agent error condition was caused by the IDB2 ssidSYSP members having an erroneous

XNETID=0000 coded in them.  The default XNETID parameter in the ssidSYSP member(s) should be kept commented out (as shipped) to allow the

identification string to be uniquely built.  This will alleviate the (rs 273) Xnet Duplicate Agent error condition.

Resolution:

The XNETID=0000 statement that was added by the customer in the IDB2 ssidSYSP member(s) was deleted, and the IDB2 data collectors were cycled.

The Sysview -MVS monitor option 6 (DB2 option) now provided metrics for all of the DB2 subsystems being monitored by the correlating IDB2

Data Collector.