Description:

When the device is kept under maintenance mode the interfaces under the devices are not reflecting the maintenance mode. 

 

Solution:

By default when the device goes down the maintenance mode will not be propagated to the interfaces.

 

If we need to propagate the maintenance mode then we need to set rollMMAlarmToIF to Yes

 

Go to the attributes of the device

Set the attribute rollMMAlarmToIF to yes

 

Now this will propagate Maintenance Mode to the interfaces/ports.

 