When starting CA InterTest batch r 9.1 the user receives 806 module CAVHINIT module not found.

Document ID : KB000038222
Last Modified Date : 14/02/2018
Show Technical Document Details

Problem: 

After completing a new install of CA InterTest batch R 9.1 the client starts the batch link facility using the common service utility program CAIRIM and receives  error messages
CAS9140E - Init errors. 
CSV003I REQUESTED MODULE CAVHINIT NOT FOUND
CSV028I ABEND806-04  JOBNAME=ÑAT035CA  STEPNAME=CAIRIM

Environment: 

Z/OS 

Cause: 

The CA InterTest batch Installation guide contained the wrong initialization card to start the batch link facility.

PRODUCT(CA InterTest Batch) VERSION(VHA0) INIT(CAVHINIT) PARM(SVC NUMBER) 

Resolution: 

The correct initialization card is  

PRODUCT(CA InterTest Batch) VERSION(MR91) INIT(MR91INIT) PARM(220) 