When promoting an element getting a C1G0259E error

Document ID : KB000098117
Last Modified Date : 06/06/2018
Show Technical Document Details
Issue:
We are experiencing a problem with promoting a element and are receiving the following messages.
C1G0259E  NO ESD RECORD FOUND IN DATASET SPECIFIED
C1G0000I     ELEMENT TPEDCNT1
C1G0000I     DATA SET SYS18137.T144637.RA000.AID0NDM.ELMOUT.H02 
C1G0134W  ELEMENT TPEDCNT1 FOOTPRINTED WITH WARNING IN DATA SET SYS18137.T144637.RA000.AID0NDM.ELMOUT.H02 
Cause:
FOOTPRNT=CREATE was specified on the temporary sequential dataset used by CONWRITE to write out the element:
 
C1G0249I  //**************************************************************
C1G0249I  //* READ SOURCE AND EXPAND INCLUDES                             
C1G0249I  //**************************************************************
C1G0249I  //CONWRITE EXEC PGM=CONWRITE,COND=(0,LT),MAXRC=0,               
C1G0249I  // PARM='EXPINCL(&EXPINC)'                                      
C1G0249I  //ELMOUT   DD DSN=&&ELMOUT,DISP=(,PASS),                        
C1G0249I  //            UNIT=&WRKUNIT,SPACE=(6160,(100,100),RLSE),        
C1G0249I  //            DCB=(RECFM=FB,LRECL=80,BLKSIZE=6160),             
C1G0249I  //            FOOTPRNT=CREATE                                   
C1G0249I  //**************************************************************
Resolution:
Endevor cannot Footprint the element written to the CONWRITE sequential data set.
The only sequential data set members that Endevor can Footprint are for OBJECT modules.
 
Remove the CREATE=FOOTPRNT from the CONWRITE &ELMOUT sequential data set