When applying maintenance to SymDump for CICS r8.5 to FMID CBQ8567 the apply is failing due to missing PTF RO64494 which is for an FMID CBQ8568 which is not have installed.

Document ID : KB000030426
Last Modified Date : 14/02/2018
Show Technical Document Details

The SMP Apply check messages below were generated since this example shows three levels of CICS installed for CA Symdump CICS r 8.5 - CICS 3.2, CICS 4.1 and CICS 4.2.

 

RO68750  CBQ8565  GIM35904I      4   PREREQUISITE SYSMOD RO64494 WAS MISSING.

                                     --- POSSIBLE CAUSES ---

                                     1. THE SYSMOD WAS NOT IN THE GLOBAL ZONE OR THE MCS WAS NOT IN THE SMPPTS DATA

                                        SET.

                                     2. THE SYSMOD WAS NOT SELECTED.

                                     3. THE SYSMOD WAS NOT A CANDIDATE BASED ON THE APPLY COMMAND OPERANDS.

 

RO68751  CBQ8566  GIM35904I      4   PREREQUISITE SYSMOD RO64494 WAS MISSING.

                                     --- POSSIBLE CAUSES ---

                                     1. THE SYSMOD WAS NOT IN THE GLOBAL ZONE OR THE MCS WAS NOT IN THE SMPPTS DATA

                                        SET.

                                     2. THE SYSMOD WAS NOT SELECTED.

                                     3. THE SYSMOD WAS NOT A CANDIDATE BASED ON THE APPLY COMMAND OPERANDS.

 

RO68752  CBQ8567  GIM35904I      1   PREREQUISITE SYSMOD RO64494 WAS MISSING.

                                     --- POSSIBLE CAUSES ---

                                     1. THE SYSMOD WAS NOT IN THE GLOBAL ZONE OR THE MCS WAS NOT IN THE SMPPTS DATA

                                        SET.

                                     2. THE SYSMOD WAS NOT SELECTED.

                                     3. THE SYSMOD WAS NOT A CANDIDATE BASED ON THE APPLY COMMAND OPERANDS.


 

PAGE 0003  - NOW SET TO TARGET ZONE CAIT1    DATE 05/18/15  TIME 14:48:47  SMP/E 36.64   SMPRPT   OUTPUT

 

 

 

Please REJECT fixes RO68750, RO68751 and RO68752. When these PTFS were created a bug in the PTF generation system added a PREREQ of RO64494 (FMID CBQ8568 ) for CICS 5.1 to the PREREQ chain of each fix, a mistake.

You then must apply RO71939, RO71940 and RO71941 which SUP the problem fixes.

 

For example CICS 3.2  fix  RO68750  FMID CBQ8565 

REJECT Problem fix RO68750 below 

APAR #: RO68750 
DESC(MAX TASK DUE TO XDUREQ WAIT). 
++VER (Z038) 
FMID (CBQ8565) 
PRE ( RO19222 RO23193 RO53341 RO55538 RO64491 RO64494 
RO64690 ) 
SUP ( AR64491 AR64494 TR68750 ) 
++MOD(IN65DSP0) DISTLIB(ABAC65 ) . 
++MOD(IN65EXT2) DISTLIB(ABAC65 ) . 
. 
.. 

Then apply RO71939 which SUPS RO68750 

APAR #: RO71939 
DESC(MAX TASK DUE TO XDUREQ WAIT). 
++VER (Z038) 
FMID (CBQ8565) 
PRE ( RO19222 RO23193 RO53341 RO55538 RO64491 RO64690 ) 
SUP ( AR68750 TR71930 TR71939 RO68750 ) 
++MOD(IN65DSP0) DISTLIB(ABAC65 ) . 
++MOD(IN65EXT2) DISTLIB(ABAC65 ) . 

 

 

 

On the apply check you must BYPASS the HOLDERROR

 

APPLY SELECT(RO71939,RO71940,RO71941)

            CHECK GROUPEXTEND
            BYPASS(HOLDERROR(AR64491,AR64492,AR64493))