What needs to happen when CA Jobtrac Job Management issues the message 'TRAC096A SYSOUT CAPTURE FULL. ENTER ACTION TO BE TAKEN'?

Document ID : KB000051517
Last Modified Date : 14/02/2018
Show Technical Document Details

Description

What actions to take when CA Jobtrac JM issues the following message:

 
'TRAC096A SYSOUT CAPTURE FULL. ENTER ACTION TO BE TAKEN'' 

Solution

If this message appears, you have three reply options: 'IGN' to ignore the error and go to the next job; reply 'ARCH' to initiate capture archive processing; reply 'ABEND' to abend the CA Jobtrac JM writer task. ARCH is the suggested reply. This unloads and archives aged sysouts, providing room for more additions. If the message continues to appear after aged sysouts have been archive, then you will need to enlarged your CA Jobtrac JM Capture file. Information on doing this can be found in the CA Jobtrac Reports, maintenance and Recovery Guide, Chapter 4, recovery section on "Moving the Sysout Capture File'.

File Attachments:
TEC523786.zip