What does User Abend 1101 on startup of CA Workload Automation EE (ESP) mean?

Document ID : KB000051602
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

IEA995I SYMPTOM DUMP OUTPUT 999           
USER COMPLETION CODE=1101       
TIME=06.25.54 SEQ=00087 CPU=0000 ASID=00A7       
PSW AT TIME OF ERROR 078D1000 96F7A460 ILC 2 INTC 0D       
ACTIVE LOAD MODULE ADDRESS=16F60000 OFFSET=0001A460       
NAME=CYBXR001       
DATA AT PSW 16F7A45A - 5800D014 0A0D9878 B11C4180       
GR 0: 00000044 1: 8000044D       
2: 001656C5 3: E2F1F0F0       
4: 000002FC 5: 17A056D0       
6: 17A04788 7: 17A03020       
8: 00000048 9: 17A047D0       
A: 16FE719C B: 00011F98       
C: 96F7A3A8 D: 16FE7128       
E: 96F4E08E F: 57E07138       
END OF SYMPTOM DUMP       
IEF450I ESP ESP - ABEND=S000 U0914 REASON=00000392       
IEF404I ESP - ENDED       
$HASP395 ESP ENDED

Solution:

Looking at the last three bytes of register 7 which are 020 this would indicate possible COMMQ data set corruption.

Start CA Workload Automation EE with PARM=CQFORMAT