Possible causes of the error PDT0511 are:

  • Detector and/or Xmanager started task is recycled: When Detector and/or Xmanager started task is recycled, Detector collections are normally and/or automatically started via the INIT option which is typically member XMANINIT in the highlvl.PXMPARM library. This member may not contain the correct information about the highlvl and datastore.

    Resolution: Verify that the highlvl and datastore information are correct.

  • Detector control file is re-initialized or changed: When the control file is re-initialized or changed, it may not recognize the datastore whose information are kept in the old control file.

    Resolution: The control file can be repro'ed from the old to the new to populate it with the information on the existing datastore; or create a new datastore after the control file is re-initialized/changed.

  • An upgrade has been done: After an upgrade, Detector collections are normally and/or automatically started via the INIT option which is typically member XMANINIT in the highlvl.PXMPARM library. This member may still contain information about the previous release's highlvl and datastore.

    Resolution: Verify that the highlvl and datastore name are correct and valid on the new release.

  • Physical datastore datasets do not exist: It is possible that the datastore datasets were created and later deleted or removed from temporay volumes due to lack of use.

    Resolution: Make sure datastore datasets are available for use.