We are getting a PSA0125 error message when starting the Xmanager

Document ID : KB000013160
Last Modified Date : 14/02/2018
Show Technical Document Details
Introduction:

PSA0125 SSA INITIALIZAION FAILED when starting the Xmanager

Question:

When I start the Xmanager why do i get this message?

PSA0125 SSA INITIALIZAION FAILED. PSACOEC0 VERIFICATIOV FAILED 

 

 

Environment:
z/os
Answer:

This is normally caused trying to load a copy of module PSACOEC0 into storage 

but it cannot because there is already a version there. 

 

Normally this is a copy from a previous release.

Things to Check

1) There is not a copy in the linklist

2) The Apf libraries do not hold a copy of the module

3) Check that the Xmanager job is using the correct and current datasets

4) Verify the datasets in the DSNAMExx member of the CDBAPARM library are correct