Warnings in uniupgrade -check due to rebranding

Document ID : KB000085644
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
In the command line where uniupgrade -check is executed: WARNING

In the the log <uniupgrade_toolkit>/log/<node>_<company>.log:
###
| 2014-12-08 16:11:10 | _______________________________________ STANDARD FILES ______________________________________ 
| 2014-12-08 16:11:10 | WARN | STDFILE | The file 'uxsetenv.bat' is customized -> Diff file is [DIFF_VMSTM2K8R2_MVEPRD_uxsetenv.bat_201412080411.txt] 
| 2014-12-08 16:11:10 | WARN | STDFILE | The file 'uxstartup.bat' is customized -> Diff file is [DIFF_VMSTM2K8R2_MVEPRD_uxstartup.bat_201412080411.txt] 
| 2014-12-08 16:11:10 | WARN | STDFILE | The file 'uxstartup_gen.bat' is customized -> Diff file is [DIFF_VMSTM2K8R2_MVEPRD_uxstartup_gen.bat_201412080411.txt]
###

Patch level detected:Dollar Universe Upgrade Toolkit 6.3.21
Product Version: Dollar.Universe 6.3.21

Description :When running the command uniupgrade -check non-relevant warning messages are reported while there is no real impact.
Environment:
OS: All
Cause:
Cause type:
Defect
Root Cause: The reference files inside the Upgrade Toolkit (uxsetenv.bat / uxstartup.bat / uxstartup_gen.bat) that are used for comparison have been rebranded to AUTOMIC S.A. This will always yield a difference with the Dollar Universe v5.6 installation.
Resolution:
Use Dollar Universe Upgrade Toolkit 6.3.41 or higher to prevent these errors

Fix Status: Released

Fix Version(s):
Component: Upgrade Toolkit
Version: Dollar.Universe 6.3.41
Additional Information:
Workaround :
N/A