The AUTOGEN and SPAN options are on two batch panels:  C1SF1000 and C1SF3000 located in the CSIQPENU library.  To disable the AUTOGEN/SPAN feature be sure to change the code on both panels.

Before the code change:

AUTOGEN (BATCH ONLY)%===>#Z+(Y/N)

SPAN %===>+(NONE/ALL/SYS/SUB)

on the bottom on the panel you will see:

.ZVARS = '(VARNOGEN VARDELIP C1SISOFR VARADDUP VAROAUTG VAROSPAN VARWKLST'

After the code change:

AUTOGEN (BATCH ONLY)%===>#Z+N (Y/N)

SPAN %===>+N (NONE/ALL/SYS/SUB)

.ZVARS = '(VARNOGEN VARDELIP C1SISOFR VARADDUP VARWKLST'

 

For modifications for QuickEdit modify the panel ENDIE150 before the code change:

Generate with AUTOGEN........_Z+(Y/N)

  SPAN (NONE/ALL/SYS/SUB)...._Z   + 

ZVARS = '(EEVOGENE EEVOCPBK EEVSIMOD EEVONSRC +                   

          EEVPRMOD EEVOAUTG EEVSOMOD EEVOSPAN EEVSYNC  EEVONLCM + 

          EEVMOVWH EEVDLMOD EEVRTNSO EEVJMPEL EEVF9NOD EEVMVMOD )'

after the code change:

Generate with AUTOGEN........_Z+(Y/N)

  SPAN (NONE/ALL/SYS/SUB)...._Z   + 

after code change:

Generate with AUTOGEN........ N (Y/N)

  SPAN (NONE/ALL/SYS/SUB)....N   + 

ZVARS = '(EEVOGENE EEVOCPBK EEVSIMOD EEVONSRC +                   

          EEVPRMOD EEVSOMOD  EEVJMPEL EEVF9NOD EEVMVMOD )'

I would recommend that all changes to any panel must be in a different library that can be concatenated ahead of the standard libraries.  That way you can revert to the standard version of the software by commenting out the modified library.