VCCCN06E Load failed for Module(VCCDIAG )

Document ID : KB000128000
Last Modified Date : 26/02/2019
Show Technical Document Details
Issue:
The VCC collector job is failing with the following message after applying MVCC maintenance to MICS libraries.
VCCCN06E Load failed for Module(VCCDIAG )
Resolution:
VCC issues this message if the LOAD for a VCC module fails, and that module is required for proper VCC operation. A LOAD failure can occur for one or more of the following reasons:
  • The modules are missing from the VCC STEPLIB data set.
  • The required STEPLIB DD statement is missing from the VCC JCL.
  • The modules are missing from the linklist
Sample JCL member VCCCOPY in library sharedprefix.MICS.CNTL should be used to copy new versions of load modules provided by a product change to an authorized library.   If using an old copy of VCCCOPY, compare against the member in MICS.CNTL to ensure all required members are specified.