USM getting alarm the following alarm corrupt PDS: can't read index 3002 from a byte buffer of length 3000

Document ID : KB000039090
Last Modified Date : 14/02/2018
Show Technical Document Details

Issue/Problem/Symptoms: 

When attempting to to access USM Alarm console, the following  error is received :

 
An unknown error has occurred.
Refreshing your browser may resolve the issue.

Details:
com.firehunter.ump.exceptions.DataFactoryException : corrupt PDS: can't read index 3002 from a byte buffer of length 3000

 

Environment:  

Issues exists in 8.0-8.31 but fix was applied in 8.4

Cause: 

large sql server alarm messages causing  error in USM alarm view

Resolution/Workaround:

The resolution is to go ahead and deploy nas 8.4 to the primary server  and after deployment to the primary go ahead and deploy ump_usm_8.2.0_HF10 to the UMP server it will restart the UMP server. This should fix the issue

Download the hot-fix from

http://www.ca.com/us/support/ca-support-online/product-content/recommended-reading/technical-document-index/ca-unified-infrastructure-management-hotfix-index.aspx

 

Additional Information: