Unresolved messages in AWI in Message Window

Document ID : KB000084346
Last Modified Date : 26/06/2018
Show Technical Document Details
Issue:
Error Message :
U00011003 Job 'XYZ' (RunID '0001031773') on Host 'ABC' aborted (return code='0001'). &06&07 &08&09
or
U00011007 Job 'XYZ' (RunID '0000999999' / Workflow-RunID: '0000999998') on Host 'ABC' ended abnormally (return code='0001'). &06&07 &08&09

In AWI in version 12.1,12.0 and 11.2 some messages in the message window are not completely resolved. 

For example: 

A job that ends with ENDED_NOT_OK has the following message in the message window: 

 
12.10.2017 13:58:38 U00011003 Job 'XYZ' (RunID '0001031773') on Host 'ABC' aborted (return code='0001'). &06&07 &08&09 
or
U00011007 Job 'XYZ' (RunID '0000999999' / Workflow-RunID: '0000999998') on Host 'ABC' ended abnormally (return code='0001'). &06&07 &08&09
Environment:
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: Some messages contained placeholders instead of information.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automation Engine 12.1.1 - Available
Automation Engine 12.0.5 – Available
Automation Engine 11.2.8 – Available
 
Additional Information:
Workaround :
The unresolved placeholders without value (&0#) have no impact, therefore they can be ignored