Issue:
Error Message :
com.ibm.msg.client.jms.DetailedJMSException: JMSCC0005: The specified value '-7260000' is not allowed for 'timeToLive'. The given value is not allowed for the property specified. Change the value to a value

When configuring a JMS Sender job and attempting to set the expiration time to a period less than one hour, the job fails with an error message similar to:

The specified value '-7260000' is not allowed for 'timeToLive'. The given value is not allowed for the property specified.

 
Cause:
Cause type:
Defect
Root Cause: Differences between timezones of Agent and Server were not included in calculations. All calculations now done in GMT.
Resolution:
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
RA JMS 2.0.0 - Available
Additional Information:
Workaround :
Configure Agent within the same timezone as Server.