Introduction:

Running Microfocus Agent Plugin. Getting a CCOND of 15.

Agent Transmitter log entry: 
CASCF0050S casgate: Console daemon not active, RC = 4605 14:11:46 
Failed to connect to regionxxxxxxx  return-code: 1- 


Question:

Trying to run the Microfocus plugin for the first time. The job fails with a ccond 15.

Agent Transmitter log entry: 
CASCF0050S casgate: Console daemon not active, RC = 4605 14:11:46 
Failed to connect to region xxxxx  return-code: 1- 


According to Micro Focus support team, the console daemon IS active. Micro Focus Console Log for the COSS region: 
170712 14515978 CASCD0131I SEP 00001 for server xxxx  has terminated normally 14:51:59 
170712 14520081 CASCD0127I SEP 00011 created forxxxxx , process-id = 59779 14:52:00

 

Answer:

Root Cause: Configuration error. BCP will need to configure the Micro Focus Enterprise Server to load the event_manager Exit Routine.