UIM- SNMPTD-How to create "PDU Variable Rules" for multiple values

Document ID : KB000112057
Last Modified Date : 30/08/2018
Show Technical Document Details
Introduction:

There is instance that more than one values for some specific variable need to be matched. 
Alarm message need to be generated when the Trap message matches one of these values .

Environment:
SNMPTD v3.30
Instructions:

1. To create the first value in UI " Create PDU Variable Rules"
    for example, var3=TEST01
2. Edit snmp.cfg to append second value
    for example, var3=TEST02
    <2>
                  var = 3
                  oid = xxxxxxxxxxxxxxx
                  op = =
                  val = TEST01
                  sev = 1
                  msg = 
                  i18n_token = 
                  order = 3
        </2>
        <2>
                  var = 3
                  oid = xxxxxxxxxxxxxxxxx
                  op = =
                  val = TEST02
                  sev = 1
                  msg = 
                  i18n_token = 
                  order = 3
        </2>

And so on

Additional Information:
Variable ID is not able to be updated in UI and has to set in config file.