U4093 during configuration cobol compile steps

Document ID : KB000004429
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

The cobol compile steps in the configuration process are all abending with U4093 in the cobol step.

 

This affects JOB14 (COBELOD5 and COBE5RPT) and JOB17 (COB5DMLC).

Environment:
CA-IDMS any supported release. Cobol V5.
Cause:

The REGION of 2048K is not sufficient.

Resolution:

Increase the REGION, ideally to REGION=0M.

Additional Information:

For further information, see the CA IDMS DocOps section on Installation and Maintenance for z/OS, Starting Your Product.