Issue:
Error Message :
U01001002 Invalid MEMSV handle.

Output-Scan with Report-Scan and more than 10 filter-criterias lead to wp-crash or "invalid memsv-handle", and the following information is written into the logs and a force trace is written
-------------
20151223/223031.772 - U01001002 Invalid MEMSV handle.
20151223/223031.772 - EXIT UCUREP RET: 0001001002 TIME: 0000,01677 RETTEXT=' ' blkcnt=0000000000'
20151223/223031.772 - U00003620 Routine 'JPEXEC_R' forces trace because of error.
.....
-------------


Error Description:
If an output-filter is defined with a report-scan containing of more than 10 filter criterias, this leads to a overwritten memory during execution, which causes either a crash or the error message "invalid memsv-handle"





 
Cause:
Cause type:
Defect
Resolution:
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Version(s):
Automation.Engine 12.0.0, Automation.Engine 10.0.8, Automation.Engine 11.1.3, Automation.Engine 11.2.1, Automation.Engine 11.1.2 HF1
Additional Information:
Workaround :
not available