U0022008 Could not start process 'UC4 ETL_Informatica-Agent'. Error Code '193'.

Document ID : KB000089249
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
U0022008 Could not start process 'UC4 ETL_Informatica-Agent'. Error Code '193'.
Resolution:
Detailed Description and Symptoms
This error message comes when the RA Informatica Agent is started but doesn't stay up.

Investigation
Not being able to start a process usually indicates a problem with permissions set on the Windows operating system for the user that is starting the Agent.

Solution
Start the agent using a user that has the correct Windows permissions as set in the Installing Agent for Windows section of the Automic OM documentation:

Act as part of the operating system
Replace a process level token
Logon as service
Logon as batch job *)
Restore files and directories
Adjust memory quotas for a process