U0011608 The internal table of active hosts is full.

Document ID : KB000084810
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
U0011608 The internal table of active hosts is full

When starting an agent > the following issue occurs and the agent got disconnected:
U0011608 The internal table of active hosts is full.




 
Cause:
Cause type:
By design
Root Cause: There is a limitation in the code when more than 15.360 agents are connected to the AE
Resolution:
Update to a fix version listed below or a newer version if available.

This was enhanced to a maximum number of Agents to 30.000 in 10.0.8 HF1

Fix Status: Released

Fix Version(s):
Automation Engine in version:
10.0.8 HF1 has been released on 2016-08-09
Additional Information:
Workaround :