TSSUTIL - TSS8007E ACCESSOR ID

Document ID : KB000018997
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

  1. Does TSSUTIL support more then one UTILIN DD option?

  2. If TSSUTIL supports more then one UTILIN DD option, is there a way to force the Job to continue with next line?

Solution:

  1. Does TSSUTIL support more then one UTILIN DD option?
    ANSWER - Yes, it does support more then one UTILIN DD option.

  2. If TSSUTIL supports more then one UTILIN DD option, is there a way to force the job to continue with the next line?
         ANSWER - The JCL example below:     ======================================================================     //UTIL1    EXEC PGM=TSSUTIL                                            //SYSPRINT DD SYSOUT=C                                                 //UTILOUT DD  SYSOUT=J,CHARS=HN12                                    //SMFOUT   DD SYSOUT=C                                                  //SMFIN    DD DISP=SHR,DSN=TSS.AUDIT1                                  //UTILIN   DD *                                                         REPORT ACID(S06A) DATE(-01) EVENT(ALL) LONG  END     REPORT ACID(S06B) DATE(-01) EVENT(ALL) LONG  END     REPORT ACID(S03) DATE(-01) EVENT(ALL) LONG END     REPORT ACID(B27Z) DATE(-01) EVENT(ALL) LONG  END     REPORT ACID(T11Z) DATE(-01) EVENT(ALL) LONG END     REPORT ACID(T13Z) DATE(-01) EVENT(ALL) LONG END     ======================================================================     ...ran until line:     ======================================================================     REPORT ACID(B27Z) DATE(-01) EVENT(ALL) LONG  END     ======================================================================     ...failed with:     ======================================================================     TSS8007E ACCESSOR ID UNKNOWN     ======================================================================

    There is no way to force the Job to continue with the next line. When specifying TSSUTIL input parameters, the ACID will be verified to see if it exists on the system where the TSSUTIL report is being run. If it doesn't exist, message

    TSS8007E - ACCESSOR ID UNKNOWN will be displayed.

    To report on the ACID receiving the TSS8007E message, TSSUTIL must be run on the System where this ACID is defined.

    If an ACID isn't specified, i.e. 'REPORT EVENT(ALL) END', then this will run on any System.

    This is working as designed. Please see Technical Document TEC484094. This document can be downloaded from the CA Web Site, CA Support Online.