TMSSTATS is abending with S0C1

Document ID : KB000107605
Last Modified Date : 23/07/2018
Show Technical Document Details
Question:
We did maintenance this past weekend and we moved some datasets to new volumes. One of them was TECH.CA1.R14.IPO2.CTAPLINK. It was supposed to get moved but was missed. But we changed SYS1.PARMLIB(PROGL2) to point to the new volume, but since it was never moved that dataset never came up in linklib. We have since added it to linklib, but when we attempt to restart TMSINIT the TMSSTATS step abended with S0C1.  How do we correct?  Also getting abends in TMSEARL jobs, U3000.
Answer:
Had him add STEPLIB's to all CA 1 jobs and this resolved the problem for now. Recommended that he re IPL with the correct libraries in PROGxx. He can then remove the STEPLIB's in the jobs.