The values of the metric physc of an entity Application are not correct (lower than expected)

Document ID : KB000085465
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Affects Release version(s): 5

Error Message :
No error appear

Patch level detected:SP Analyst Agent for Unix 5.60
Product Version: Sysload 5.6.0

Description :The values of the metric physc of an entity Application are not correct ( lower than expected)
Environment:
OS: IBM AIX
Cause:
Cause type:
Defect
Root Cause: N/A
Resolution:
The calculation rule for the metric %physc for a given process has been changed to:

PHYSC_proc = PHYSC_LPAR * %CPU_TOTAL_proc / %CPU_TOTAL_LPAR

instead of:

PHYSC_proc = PHYSC_LPAR * %CPU_TOTAL_proc / 100

Fix Status: Released

Fix Version(s):
Component: Agents
Version: Sysload 5.8.0
Additional Information:
Workaround :
N/A