The time range pull-down menu for SLA reports in the APM CE (CEM) GUI is missing.

Document ID : KB000007245
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

 The time frame drop-down box does not show up at all. The result is not being able to select the desired SLA report time frame and generate a report.

CEM_TIME_RANGE_OFF.png

Also the Usergroup drop-down box shows abnormal values:

cem5.png

Environment:
All supported APM releases running CEM.
Cause:

   The likely cause is a mismatch during user group identification. This matching issue is due possibly to to a user group length of more than 200 characters. The result is the page alignment being displayed incorrectly.  

Resolution:

After having a backup of the APM database, perform one of these two operations.

  1. Correct the user group identification from the business application settings.

  2- Delete the user group from the APM CE (CEM) setup UI.

 

Restart the cluster after making these changes.