The SPM Test for URL monitoring fails with the following error on the Spectrum OneClick Console: SPC-OCC-10183: The following errors(s) occurred when attempting to run the selected test(s): SPC-OCC-1641: Failure.

Document ID : KB000008196
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

The SPM Test for URL monitoring fails with the following error on the Spectrum OneClick Console:

SPC-OCC-10183: The following errors(s) occurred when attempting to run the selected test(s):

SPC-OCC-1641: Failure.

 

Environment:
Applicable to all version of CA Virtual Assurance for Infrastructure Managers.
Cause:

The URL monitoring test fails with status 'Bad Configuration' because the read community string is being configured at the SystemEDGE Agent side.

The read-write community string must be configured for the URL monitoring to work properly.

 

Resolution:

Please edit the sysedge.cf file under the port161/1691 directory on the agent and configure it to read-write community string, then on the Spectrum OneClick Console change the community string to read-write for the agent. Please poll the device again for the changes to take effect.

 

 

Additional Information:

For additional information, please refer to the Service Response Monitor User Guide:

https://support.ca.com/cadocs/0/CA%20Virtual%20Assurance%20for%20Infrastructure%20Managers%2012%208-ENU/Bookshelf_Files/PDF/VA_SRMUser_ENU.pdf