The PE025 error occurred in the "%INPUT DCONVERT,*" process

Document ID : KB000038534
Last Modified Date : 14/02/2018
Show Technical Document Details

Summary:

When we executed the "%INPUT DCONVERT,*" job, we recieved the "PE025 16-16 FILE ORG CONFLICT PDSOUT *" error message.
What is the cause of this error ?
How to solve this error ?

            %FETCH  PANELIB *TEST    .ELEMENT1/EXEC    ;TA                          \DECONV\
PE025 16-16 FILE ORG CONFLICT PDSOUT *
            %FETCH  PANELIB *TEST    .ELEMENT2/EXEC    ;TA                          \DECONV\
PE025 16-16 FILE ORG CONFLICT PDSOUT *



Instructions:

Please check the TYPE of target element, and the DCB of PDSOUT file.
When the TYPE of element and the DCB information of PDSOUT file do not match, this error occurs.

For example;

Element Type       PDSOUT File DCB
-------------------------------------------------------------------------------
EXEC               DSORG=PO, RECFM=FB, LRECL=80, BLKSIZE=27920    -  ERROR
EXEC               DSORG=PO, RECFM=U, LRECL=0, BLKSIZE=32760      -  CORRECT

DATA               DSORG=PO, RECFM=U, LRECL=0, BLKSIZE=32760      -  ERROR