The client just installed CA Intertest for CICS r 10 and when he starts his CICS region he abends with and AEYO abend at start time.

Document ID : KB000007962
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

The clients software factory installed and rolled out a new version of CA Intertest for CICS r 10. The customer upgraded from release 9.1 to r 10.  When the client started their CICS region they received an abend at PLTPI time in program IN25PLT. The abend code is AEYO.

Environment:
Z/OS CICS
Cause:

When the client installed CA Intertest for CICS the client only applied one CA Intertest for CICS FMID 

CCSAA00 /*InterTest CICS Component

Resolution:

A  standalone CA Intertest for CICS r 10 only installation requires the following FMIDS to be applied for a valid install.

CCSAA00 /*InterTest CICS Component
CABAA00 /*Common CICS Component
CAVHA00 /*Common Symbolic Component
CABAA01 /*Common CICS DB2 Component   Optional if not licensed for DB2

The software factory reinstalled the product with the required FMID'S.