The client is upgrading to VSE 6.2 for CA Intertest for CICS VSE. Is fix TE61063 and same as fix T561063?

Document ID : KB000103178
Last Modified Date : 22/06/2018
Show Technical Document Details
Question:
When upgrading to VSE 6.2 the client is required to apply fixes TC23605, TC23606, T561063 to CA Intertest for CICS VSE release 6.0 . The client already has fix TE61063 applied for a previous problem which alters the same instructions as fix T561063. Is fix T561063 is permanent version for TE61063? 
 
Environment:
VSE
Answer:
Fixes TE61063 and T561063 are identical fixes. So the fix required for VSE 6.2 is already applied.
 
Below is fix TE61063.
 
CORR 0202-IRH08-VS2:TE61063
 
CORR 0202-IRH08-VS2:TE61063
REQ PRE=(QO82058,RO01079)
AFF PHASE=IN25PGMS
ALT 007CF4 00018000:0005FFFF
ALT 00B392 F2F1F7:F2F2F1
 
Below is fix T561063
 
// JOB T561063
*
* PRODUCT: CA-INTERTEST-VSE REALIA II HTO RELEASE: 6.0
*
* PROB #: 000706 FN: T561063 FT: INTCOM DATE: 16 JUL 2008
*
* CICS411 IADS ABEND IN IN25PGMS WHEN MONITORING.
* ---------------------------------------------------
*
* PROBLEM RESOLUTION: Apply the following PTF to the system.
* Reload any resident modules, or re-IPL if necessary.
* ***NOTE*** Retain the printed output for reference.
*
* REQ PRE=(QO82058,RO01079)
*
// DLBL IJSYSHF,'INSTALL.HISTORY.FILE',99/365,SD ,99/365,SD
// EXTENT SYS011,VOLIDX,1,0,XTN1,XTN2
// ASSGN SYS011,DISK,VOL=VOLIDX,SHR
// DLBL CAIILIB,'INSTALL.LIBRARY.NAME'
// EXTENT ,VOLIDX
// EXEC MSHP,SIZE=768K
CORR 0202-IRH08-VS2:TE61063
REQ PRE=(QO82058,RO01079)
AFF PHASE=IN25PGMS
ALT 007CF4 00018000:0005FFFF
ALT 00B392 F2F1F7:F2F2F1
/*
/&