The CA Intertest CICS VRPT transaction shows message Program release mismatch.

Document ID : KB000007632
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

The client sucessfully implemented CA Intertest R10 in about 30 CICS regions. When the client upgraded a few more regions they received the following error message in the VRPT transaction. IN25OPTS V9.1 RI12570 - CICS 6.7.0 - Program release mismatch

Environment:
Z/OSCICS
Cause:

The client had an old version of the IN25OPTS module from release 9.1 in the  CICS RPL concatenation.

Resolution:

Search all the load libraries in the  CICS RPL concatenation and find the old version of IN25OPTS from release 9.1 and remove it.