Testrunner does not finish test suite

Document ID : KB000005166
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

We try to run a test suite in Test Runner and it ends prematurely as successful.  We do not know why it ends early as there is not an error message.

Environment:
All supported DevTest versions
Cause:

This is caused by the max errors set in the staging document.

 

https://docops.ca.com/devtest-solutions/9-5/en/using/using-ca-application-test/using-devtest-workstation-with-ca-application-test/building-documents/building-staging-documents/staging-document-editor/staging-document-editor-reports-tab

 

  • The Maximum number of errors before test is stopped field limits the number of errors that the test can have before LISA aborts it. A zero entry means to allow all errors.
Resolution:

Increase the max errors to the number required or set it to unlimited by setting it to 0

Additional Information:

n/a