Systems Performance Lite Real-Time Agent has stopped working/Faulting application rtaAgent.exe

Document ID : KB000050123
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

On windows 2008 Server, the application logs shows that the RTA has stopped working.

You will observe the following message in the Application event logs:

Problem Details:
Log Name : Application
Source : Application Error
Date : 27/05/2011 16:37:03
Event ID : 1000
Task Category : (100)
Level : Error
Keywords : Classic
User : N/A
Computer : xyz

Description:
Faulting application rtaAgent.exe, version 11.0.0.1, time stamp 0x4994858d,
faulting module AwMsq.dll, version 6.0.6002.18005, time stamp 0x49e03824,
exception code 0xc0000135, fault offset 0x0006f04e, process id 0x13a0,
application start time 0x01cc1c494107b4ab.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">

Solution:

The solution is to add a semi-colon ';' at the end of PATH environment variable.

Add a character ';' at the end of PATH environment variable and restart service "CA Systems Performance LiteAgent".

rtaagent.exe should now be able to start without crashing.

Note: Please update the PATH variable via System Properties (sysdm.cpl) and not via the comand prompt.