Issue:
Cust created a new system image:  Version 0005. Cust changed this  from version
0002 to 0005 in the AUTOIDS - Automation Identifiers (/PARMS then select
$RM AUTOIDS). It was saved with PF4 or PF3 (cust tried both).

So cust expected by the next startup of NetMaster that image 0005 would be load-
ed. But when they looked again in the $RM AUTOIDS, after NetMaster was
recycled, the version was back to 0002 and image 0002 was loaded. 
Environment:
OS: z/OS.
Resolution:
Indeed cust found--from CA Support verification suggestion--that INIFILE was
being used on the NM startup and in it there was an entry which caused image
0002 to be loaded when NetMaster was started up.   Cust was going to change
that to the right image.
Additional Information:
See Product Region NCL Parameters on the NetMaster documentation for the
INIFILE parm details.