Issue:

The Sybase probe will not start with the following error in the sybase.log file located in the probes installation directory:

Probe 'sybase' FAILED to start (command = sybase_monitor.exe) error = (2) The system cannot find the file specified.

Environment:
UIM 8.x
Cause:

Sybase probe was installed on a server remote to the Sybase server.

Resolution:

Make sure that the Sybase probe was installed directly on the Sybase server.