Issue:

After restart tests hosts are going into maintenance mode even though the device is normal

Environment:
10.2.1
Cause:

Whenever we restart spectrum services the tests hosts will go into maintenance.

Once Spectroserver activated all the device models got activated then it will check the device contact status is active and it resets the state of the test host to active.  

Currently random test hosts are getting selected because of threads which is causing the issue.

 

Resolution:

 

patch 10.02.01.D218a resolves this issue

In this patch 10.02.01.D218a scheduling the thread is corrected so that it will consider all the test hosts which are there in the host table

instead of the random test hosts.
 