SPM TEST HOST CONFIGURATION FAILURE - UNABLE TO PERFORM TEST

Document ID : KB000113481
Last Modified Date : 11/09/2018
Show Technical Document Details
Issue:
SPM ICMP test created on OneClick Console does not run on Cisco device. These are the symptoms observed: 
- The test state goes to Disabled. 
- The test status is Device Disabled. 
- The test state is Maintenance 
- When manually run the test, the following message is displayed: 
SPC-OCC-10183: The following error(s) occurred when attempting to run the selected test(s): 
SPC-OCC-11641: Failure. 

After set RW SNMP Community String from RO to RW on the modeled device, the test Status is now Bad Configuration. 
Environment:
CA Spectrum 9.x, 10.x
Resolution:
Deleted and rediscover the Cisco device with Read Write SNMP Community String. As it was previous modeled using Read Only Community String