Spectrum SpectroSERVER won't start after reboot and/or OS patch installs

Document ID : KB000092661
Last Modified Date : 20/04/2018
Show Technical Document Details
Issue:
After doing a restart of the server on which the SpectroSERVER is installed you are no longer able to start the SpectroSERVER. You can see some or all of the following occur:

1) The SpectroSERVER starts and gets an immediate shut down signal and stops.
2) When trying to start the Spectrum Control Panel you can see "Error connecting to LocServ: org.omg.CORBA.OBJECT_NOT_EXIST: vmcid: 0x0minor code: 0 completed: No" in the SCP.OUT.
3) Logs are not updating or being created new
Environment:
Windows or Linux
All Spectrum Versions
Cause:
This is due to a permissions issue with the user. Seeing no logs update or created along with one of the other 2 issues is a good indicator.
 
Resolution:
On both Windows and Linux:
-Check that the user permissions/group have not changed
-Check the user is still part of the correct AD/security group