Spectrum - eHealth integration test fails: "Error saving to ehealth-config.xml: Initial eHealth Integration configuration still in progress. MySQL may be down".

Document ID : KB000051863
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

The error logged in the stdout.log: Schema change summary for "eHealth Integration." No schema changes need to be applied. See solution for balance of error.

Solution:

This error occurs if the SpectroSERVER is down and unreachable when Spectrum tomcat is started. This causes problems with initialization of the integration.

At least one SpectroSERVER must be up and running before starting Spectrum tomcat. A restart of the Spectrum Tomcat service should resolve the issue.

This is not an issue in Spectrum 9.2.

Full error logged in stdout.log:

Schema change summary for eHealth Integration--------------------------------------------------------------- No schema changes need to be applied. Jul 1, 2010 10:21:09 AM - (EhealthSyncDiscovery) - INFO - EHealth Synchronized Discovery initializing...Jul 1, 2010 10:21:10 AM - Error starting eHealth mapping services for psl-ehealth.polaris.co.in. Please check configuration.com.aprisma.spectrum.app.ehealth.common.EhealthException: Initial eHealth Integration configuration still in progress. MySQL may be downJul 1, 2010 10:21:28 AM - (EhealthSyncDiscovery) - ERROR - An eHealth discovery was successfully launched, but there was an error sendingthe event to the EHDiscPolicy model