SPC-SDN-5: Error Saving to Database:Modeling is in progress. Integration cannot be disabled now..

Document ID : KB000008574
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

When the customer tries to disable the VNA integration they receive the following error: SPC-SDN-5: Error Saving to Database:Modeling is in progress. Integration cannot be disabled now..

Environment:
Spectrum 10.2.xVNA 3.2
Cause:

During the integration of VNA into Spectrum devices that are known to VNA get modeled in Spectrum. If for any reason this process stalls the integration cannot be disabled.

Resolution:

In the OneClick GUI Select the SDN Manager model.

Go to the Component Details -> Attributes Tab

Search for the attribute: SDN_ModelingInProgress

Double click on the SDN_ModelingInProgress and change the value to False

Once complete please disable the integration.

Please note: When removing the integration the models added by VNA will be removed. If the above steps are followed some models that were added by the integration may need to be manually destroyed.

Additional Information:

Spectrum 10.2.x

VNA 3.2