Some Actions not blocked when a Sub-Job ends "NOT OK"

Document ID : KB000087536
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
N/A

The following action:
 
PACKAGES/PCK.AUTOMIC_FILESYSTEM/ACTIONS/FILE/FILESYSTEM/PCK.AUTOMIC_FILESYSTEM.PUB.ACTION.SNAPSHOT_CREATE 
will not block when PCK.AUTOMIC_BOND.PRV.JOB.SNAPSHOT.CREATE_GUID@UNIX (or WINDOWS) fails because the end-object of that JOBP has its dependencies set to "All states must match" to "" (nothing at all).  See screenshot below.
0EMb0000001QP2Z.png

Expected: This workflow should be blocked when the Sub-Job fails.
Cause:
Cause type:
Defect
Root Cause: "End" object of workflow PCK.AUTOMIC_BOND.PUB.ACTION.SET_ENVIRONMENT_GUID has its dependencies set "All states must match" to "ANY_OK"
Resolution:
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Package.Filesystem 1.2.1 - Available
Additional Information:
Workaround :
N/A