SETUP.LST file could not be copied

Document ID : KB000087758
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
Could not open the file named:
C:\temp\AEInstallImages\AutomationEngine_full\11.2\Automation.Engine_Image_11_2_15-12-18-1\AutomationEngine\windows\x64\SETUP.LST

SETUP.LST
The SETUP.LST file could not be copied - Setup cannot continue.

When running the setup.exe from the Automation Engine (AE) installation image, the installation fails and the following messages are displayed.
 
0EMb0000000HlUz.png
0EMb0000000HlV4.png
Cause:
Cause type:
Configuration
Root Cause: File path is too long.
Resolution:
Make the path shorter before running the setup.exe. For example, copy the ...\AutomationEngine\windows\x64 to the C: directory.

Fix Status: No Fix

Fix Version(s):
N/A
Additional Information:
Workaround :
N/A