We can use the value of a variable binding for the alarm title.
Instructions:
Add a dynamic alarm title and test in OneClick

C:\win32app\Spectrum\custom\Events\AlertMap
1.3.6.1.4.4.1.6.3 0x050e1106 1.3.6.1.4.1.10.1.1(76620,0)

• The OID map contains the variable bindings that are sent with the traps
    • The value in front of the ‘(’ is the variable binding OID
    • The first value inside the parenthesis is the event variable ID which will contain the variable binding value
    • The second value inside the parenthesis is the event variable ID which will contain the instance portion if the variable binding is a row of a table object

C:\win32app\Spectrum\custom\Events\EventDisp
0x50e1106 E 50 A 1,0x50e1106,76620

Edit the 0x50e1106 event message in Event Configuration Editor to output the variable bindings as follows:
The value of the dynamic alarm title at  1.3.6.1.4.1.10.1.1 is  {S 76620}

Send a trap with the above AlertMap mappings to populate the 0x12b4c (76620 in decimal) and use EventDisp to create an event that alarms.