Scheduler does not show correct status of started Task in AWI and Java GUI

Document ID : KB000084561
Last Modified Date : 14/05/2018
Show Technical Document Details
Issue:
Error Message :
N/A

A scheduler (JSCH) has a planned start of an executable object. It affects all executable objects except Workflows (JOBS). Before the executable object starts (in the screenshots it is a JOBS), its status in the Schedule Monitor is correctly given with Waiting for start time:

0EM0N000001i5jT.png

Now the Job starts. Its own Executions show Still active:

0EM0N000001i5jY.png

In the Schedule Monitor, the status of the job goes to Ready for generation:
 
0EM0N000001i5ji.png

From now on it remains in this status. Even after the Job is finished:

0EM0N000001i5jn.png

it remains in Ready for generation:

0EM0N000001i5js.png
Cause:
Cause type:
Defect
Root Cause: The monitor of a schedule object is not updated during the execution of a task. Task state is set to "ready for generation" but not updated any more afterwards if the state of the sub-task is changed.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: In Progress

Fix Version(s):
AE Server and Initialdata

Automation Engine 12.2.0 - Planned release date: 2018-06-19
Automation Engine 12.1.2 - Planned release date: 2018-05-21
Automation Engine 12.0.5 - Available