SC13-10 abend running a CA JCLCheck Workload Automation job with concatenated input PDS data sets

Document ID : KB000020579
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

When running a CA JCLCheck WA job having more than one input PDS data set (SYSIN DD is concatenated), and runtime option DIRUPD is also used, CA JCLCheck failed with error:

IEC153I C13-10,IFG0194A,jobname,stepname,SYSIN-0002,device#,serial#,dsname
What should you do in this case?

Solution:

If the SYSIN DD must be concatenated using PDS dataset, remove runtime option DIRUPD or disable it by specifying option NODIRUPD.
Option DIRUPD (Directory Update) is used by the CA JCLCheck /CA APCDOC interface.

Error C13-10 occurs when a concatenated PDS is OPEN for OUTPUT or EXTEND.
Option DIRUPD causes CA APCDOC to open the SYSIN PDS file for OUTPUT processing. The SYSIN DD is concatenated thus error C13-10 error is issued.
CA JCLCheck r11 supports concatenated input PDS data set, but CA APCDOC does not.