Runtime Analyzer Module crashes in PR with U1030 or U0223 in $JCLRA12

Document ID : KB000087757
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
UCR0178A NO CSA NODES AVAILABLE FOR RUN MODULE

Runtime Analyzer Module crashes in PR with U1030 or U0223 in $JCLRA12

Production Run jobs abended in the Restart Plus Runtime Analyzer Module Step:
UC4 RestartPlus - U1030 or U0223 in $JCLRA12

0EMb0000001UR7l.png

0EMb0000001UR7q.png


In the Supervisor Task no messages were shown at that time.

A bug was fixed, where RestartPlus runtime module has crashed due to shortage of CSA communication buffer.

Message UCR0178A in JES log identifies the problem:
UCR0178A NO CSA NODES AVAILABLE FOR RUN MODULE
Fix increases CSA buffer size up to 8192 CNBLOCK slots.
 
Environment:
OS: MVS
Cause:
Cause type:
Defect
Root Cause: A bug was fixed, where RestartPlus runtime module has crashed due to shortage of CSA communication buffer.
Fix increases CSA buffer size up to 8192 CNBLOCK slots.
Resolution:
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Restart.Plus 1.2O
Additional Information:
Workaround :
n/a