RSET in Post-Process shows different behavior after a restart

Document ID : KB000087749
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
n/a

If a variable with value "" (null) within a Post-Process / Post-Script of a task is inherited with RSET, the restart will cause that a blank is read out in Postscript out of the variable.

Value in Post-Process before of restart:
2016-04-14 13:23:55 - U00020206 Variable '&VAR#' was stored with value ''.
Value in Post-Process after restart:
2016-04-14 13:24:35 - U00020206 Variable '&VAR#' was stored with value ' '.
 
Cause:
Cause type:
Defect
Resolution:
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Automation.Engine 11.1.4 in AutomationEngine - already released
Automation.Engine 11.2.2 in AutomationEngine - already released
Additional Information:
Workaround :
n/a