RMOSTC Task Fails with S052 Abend

Document ID : KB000029064
Last Modified Date : 14/02/2018
Show Technical Document Details

Solution:

  • Issue "/S rmostc,PARM=OFF"
       The RMOSTC task will come up, then go down, properly removing the "hooks".
  • Change the RMOPARM SYSID, to another and unique value.
  • Issue "/S rmostc" 
       The RMOSTC task will start.

Changing the RMOPARM SYSID, to another value, will cause a new program call to be assigned, which will prevent the abend.